Bi-Directional Amplifier (BDA) Comparison Chart
| Product Name | Fiplex DH7S-D-S27AH - DIGITAL SIGNAL BOOSTER. PS 800 MHz, High Capacity Single Band +27dBm, Class A, 64 filters, NFPA, DC. | Fiplex DH14CA-AV-ND - DIGITAL SIGNAL BOOSTER.VHF 136-174MHz, +24dBm, 32 filters +2 Adj sub bands, NFPA, class A, AC & DC, No Internal Duplexer | Comba Public Safety 27dBm Class A Dual Band 700MHz BDA (AC/DC) | Comba Public Safety Class A UHF 450MHz to 512MHz BDA (AC/DC) - 2 Window Passband | TruePath - Class B 700 and 800 MHz Public Safety BDA, 1/2 Watt, AC |
|---|---|---|---|---|---|
| Brand |
|
|
|
|
|
| Supported Bands | 800 | VHF | 700 | UHF (Includes T-Band) | 700/800 Dual-Band , Band 14 |
| Class | A | B | A | A | B |
| Uplink Frequencies in MHz From | 806 | 136 | 788 | ||
| Uplink Frequencies in MHz To | 824 | 174 | 824 | ||
| Uplink Frequencies in MHz | From: 806 MHz To: 824 MHz | From: 136 MHz To: 174 MHz | From: MHz To: MHz | From: MHz To: MHz | From: 788 MHz To: 824 MHz |
| Downlink Frequencies in MHz From | 851 | 136 | 758 | ||
| Downlink Frequencies in MHz To | 869 | 174 | 896 | ||
| Downlink Frequencies in MHz | From: 851 MHz To: 869 MHz | From: 136 MHz To: 174 MHz | From: MHz To: MHz | From: MHz To: MHz | From: 758 MHz To: 896 MHz |
| Uplink Composite Power in dBm | 24 dBm | 24 dBm | 27 dBm | ||
| Downlink Composite Power in dBm | 27 dBm | 24 dBm | 27 dBm | ||
| Power Consumption in Watts | 80 Watts | 100 Watts | 160 Watts | ||
| 2524 NRTL for Listed Products | SGS | SGS | SGS | SGS | UL |
| 2524 Listing Status | Listed | Listed | Listed | Listed | Listed |
| 2524 Certification Date | |||||
| STD 2524 Comments | Investigated to UL2514 - 2nd Edition Revised 2019-02-28, Bi-directional amplifier | ||||
| Other Certifications | FCC, NFPA, Buy American Compliant | FCC, NFPA, Buy American Compliant | UL 60950-1 & UL 60950-22 Compliant | UL 60950-1 & UL 60950-22 Compliant | CAN/CSA-C22.2 No. 62638-1. FCC Part 20 Part 90 |
| Website Link or Product Page | https://fiplex.com/flex-in-building-solution/ | https://fiplex.com/flex-in-building-solution/ | 7831851-0013 | ||
| Notes | www.fiplex.com |
www.fiplex.com Other internal duplex and option are available. Please call your Sales Rep or send an email to presales@fiplex.com |
Wireless Supply also offers our BDA products as a kit which includes the BBU, annunciator, and alarm junction boxes for connection to a buildings fire alarm panel | ||
| Organization Name | Honeywell-Fiplex | Honeywell-Fiplex | Comba Telecom, Inc. | Comba Telecom, Inc. | Wireless Supply, LLC |